Concentrated solar power (CSP) technologies: Status and analysis

3 de abril de 2023

Concentrated solar power (CSP) technology is a promising renewable energy technology worldwide. However, many challenges facing this technology nowadays. These challenges are mentioned in this review study. For the first time, this work summarized and compared around 143 CSP projects worldwide in terms of status, capacity, concentrator technologies, land use factor, efficiency, country and many other factors.

 

Further, the various challenges facing the spread-out of this system are highlighted in terms of the heat transfer fluids (HTF), various energy storage (ES) technologies, cooling techniques, water management, and the Levelized Cost of Electricity (LCOE). Also, various thermophysical properties of the HTF are compared within the applicable range of the CSP operation. At the end of the review, various hybridization technologies for the CSP with various renewable energy sources, including photovoltaic, wind, and geothermal, are highlighted and compared. The pioneering country in using CSP, leading concentrator technology, suitable ES technology, and efficient hybrid technique based on the LCOE are determined. The analyzed data in this study is essential for predicting the future of the CSP in the markets and its contribution to reducing global warming potential.

Keywords

Concentrated solar power
Thermal energy storage
Levelized cost of electricity
Hybrid renewable energy systems
Heat transfer fluids

1. Introduction

Around 600 million people in Sub-Saharan Africa lack access to electricity, and about 940 million rely on hazardous fuels such as firewood and charcoal for cooking [1]. Most electric power generation systems do not store energy since doing so would be extremely expensive. The utilities must thus utilize more fossil fuel-burning facilities to ramp up or down as necessary to meet demand. However, this strategy is not ideal because these plants function more effectively at full power [2]. To fulfill the demand for electricity demand effectively offset the shortage of energy sources, it is advised that renewable energy systems integrated with different types of energy storage systems be implemented. Due to the projected 5.8% rise in global power consumption in 2022, large-scale renewable energy projects are being installed all over the world [3]. As a result, the percentage of renewable energy in the energy mix has increased significantly. However, additional renewable energy projects are needed to supplement or replace the lack of conventional sources of energy [4,5]. The percentage of renewables in power generation in the United States is predicted to rise by 23% by the end of 2050, as shown in Fig. 1-a. Further, Fig. 1-b shows the history and the projection of renewable energy sources in the US. It is expected that solar energy plays an important role in the US energy expected electricity production with a percentage of 51% followed by wind and hydroelectric power technologies [6,7]. Worldwide, Fig. 2 shows the electricity generation breakdown projection in 2050. It is expected that renewable energy will contribute to around 85% of global energy production. In addition, there is a great expected dependence on wind energy followed by solar PV and a slight dependence on the CSP with a percent of 4%.

Fig 1

  1. Download : Download high-res image (409KB)
  2. Download : Download full-size image

Fig. 1. United States energy mix projections in Trillion kWh; (a) Energy mix share projections, (b) Renewable energy sources utilization projections in the United States [6].

Fig 2

  1. Download : Download high-res image (315KB)
  2. Download : Download full-size image

Fig. 2. Electricity generation breakdown projection of the world in 2050 [7].

Photovoltaics (PV) and wind are the most renewable energy technologies utilized to convert both solar energy and wind into electricity for several applications such as residential [8,9], greenhouse buildings [10], agriculture [11], and water desalination [12]. However, these energy sources are variable, which leads to huge intermittence and fluctuation in power generation [13,14]. To overcome this issue, researchers studied the feasibility of adding energy storage systems to this power plant [15,16]. Concentrated solar power (CSP) is a promising technology to generate electricity from solar energy. Thermal energy storage (TES) is a crucial element in CSP plants for storing surplus heat from the solar field and utilizing it when needed.

Based on the recent report by IEA, the roadmap of the CSP concluded the following: it is expected by 2050, with suitable governmental support, CSP could generate 11.3% of global electricity demand, with 9.6% from solar energy and 1.7% from backup fossil or biomass fuels. Further, all CSPs have the chance to apply thermal storage. It is also road mapped that North America is the largest producing and consuming region for CSP electricity, then Africa, India, and the Middle East. Furthermore, Northern Africa has the high potential to be an electricity seller to Europe due to the high solar irradiance, which compensates for the extra cost caused by the additional transmission lines. IEA also clarified that the CSP could be implemented in different high-temperature water desalination applications in arid countries.

One of the key challenges facing the spread of the CSP in hot arid areas is the required cooling water for the operation of the power block and mirrors cleaning. In addition, the main restriction for expanding the CSP is not the availability of the area suitable for the operation, but the far of the locations from the consumption center is another issue still facing the technical and economic concerns of the constant electricity transportation. The Levelized Cost of Electricity (LCOE) of CSP plants has been decreasing over the past several years, and by the end of 2021, the LCOE fell below 0.1$/kWh as seen in Fig. 3 reported by the International Renewable Energy Agency (IRENA).

Fig 3

  1. Download : Download high-res image (400KB)
  2. Download : Download full-size image

Fig. 3. Levelized cost of electricity for CSP [17].

The effectiveness of CSP plants lies in their capabilities to store large amounts of thermal energy that are collected during the day using thermal energy storage, allowing the plant to store this energy and dispatch it during the night. As a result, CSP plants can deliver power on demand, giving them an economic advantage over other renewable energy technologies [18]. In addition, resulting in 25% increase in electric power generation [19]. Since waste heat recovery has already proven useful in various other contexts [20], [21], [22], [23], it may be possible to implement it in CSP operations. The energy produced by the different renewable energy sources might be stored using a variety of energy storage systems, including; supercapacitors [24], fuel cells [25], Battery Energy Storage Systems (BESS) [26], thermal energy storage [27], compressed air systems [28] and hydropower dams [29,30].

CSP technology may have both beneficial and harmful effects on the natural environment. CSP technology has the advantage of not contributing to global warming [31], [32], [33]. CSP systems are more environmentally friendly in regions with limited access to fresh water since they use less water to operate than conventional fossil fuel power plants [34,35]. CSP systems also need less land for each unit of electricity generated as compared to other renewable energy sources like wind and solar photovoltaics [36]. The use of CSP technology does, however, have certain unintended and perhaps harmful effects on the surrounding environment. Land use and the resulting loss of habitat are a major source of damage. Large areas of land must frequently be removed for CSP systems, which may have a severe effect on the surrounding environment and wildlife habitat [37], [38], [39]. The usage of harmful materials is another possible drawback. Unsafe disposal of lead or sulfuric acid, used in certain CSP systems, may have serious consequences for human health and the environment [40,41]. Furthermore, the noise pollution created by certain CSP systems might harm surrounding wildlife [42].

The Sustainable Development Goals (SDGs) framework was developed as a response to these consequences. The framework is a collection of rules intended to encourage Renewable Energy development and operation in a way that makes it more environmentally friendly. Reducing the wasteful use of land and the loss of natural habitats are two of the framework’s primary aims. Developers are urged to make use of degraded or previously disturbed land instead of areas with ecological systems and animal habitats. As a further measure, the framework pushes for water-saving tools and methods. Developers are also urged to reduce or eliminate the usage of any potentially harmful substances. In order to reduce noise pollution, the framework also advocates for noise-reducing technology and behaviors [43].

There are many recent studies focused on CSP technologies. However, this study focuses on exploring the status and challenges facing the CSP. This can be attained by summarizing the status of 143 CSP projects worldwide in terms of capacity, concentrator technologies, land use factor, efficiency, country, and many other factors. Also, the challenges facing this technology are highlighted in terms of heat transfer fluids (HTF), energy storage (ES) technologies, cooling techniques, water management, and the Levelized Cost of Electricity (LCOE). At the end of the review, a comparison is conducted for the possible integration methods of renewable energy sources with the CSP. The impact of COVID-19 period on the installed capacity of the CSP is also presented.

2. CSP technologies, installation developments, and existing capacities

CSP technology generates electricity by concentrating solar rays into a heat absorption receiver. It has been determined that CSP-based technology is appropriate for areas with a high Direct Normal Irradiation (DNI).

There are four most common CSP technologies available in the markets. First, parabolic trough systems which consist of parallel rows of curved high-reflectance mirrors. Sometimes it can extend to more than 100 m long. The receiver tube is made of stainless-steel pipes (called absorber tubes). These tubes are coated with a selective coating to absorb the short-wavelength or high-energy solar radiation. Due to the solar irradiance absorption, the absorber tube temperature increases; therefore, it is insulated by a vacuum layer from the atmospheric condition. Inside the absorber tubes, different types of oil are commonly used as heat transfer fluid to collect the heat and transfer it to the energy storage units and the steam generator in the Rankine cycle. Some newer plants have significant thermal storage capacities.

Second, Linear Fresnel reflectors (LFRs) Fig. (4-A), are similar to the parabolic trough, but they use linear rows of mirrors to reflect the sun rays onto a flat fixed receiver. LFR systems have a simple fixed receiver design with a low investment cost for direct steam generation. But it is less efficient than troughs in converting solar energy to electricity. Thirdly, solar towers or central receiver, Fig. (4-B), uses thousands of heliostats to concentrate the sun rays to one central receiver placed at a high level of the constructed tower. The high concentrated heat flux is used for direct steam generation, or molten salt can be used directly in the receiver. Very high temperatures can be obtained using this system. Finally, the parabolic dish CSP used a dish to concentrate the DNI to a central point. At the central point, Stirling engines are mostly used to convert the concentrated heat to useful mechanical energy then electrical energy in the generator. The whole system tracks the sun. Most dishes have an independent engine/generator (such as a Stirling machine or a micro-turbine) at the focal point. This design eliminates the need for a heat transfer fluid and for cooling water.

Fig 4

  1. Download : Download high-res image (573KB)
  2. Download : Download full-size image

Fig. 4. Schematic layout of the CSP uses (A) Linear Fresnel reflectors and (B) Solar tower.

Fig. 5 shows the schematic layout of the CSP system using a parabolic trough. The power block, thermal energy storage, and solar field are the three primary parts of CSP systems. The solar field concentrates the sun’s rays, which are subsequently converted into thermal energy. Therefore, the heat is used to generate steam, which in turn drives the power block to generate electricity. In the case of high larger solar multiple, a high amount of heat can be captured. This heat can be stored in a thermal energy storage system. One of the most common and less expensive technology is the use of two-tank molten salt.

Fig 5

  1. Download : Download high-res image (504KB)
  2. Download : Download full-size image

Fig. 5. Schematic layout of parabolic trough CSP with two molten salt thermal energy storage.

CSP facilities may be divided into two classes based on the types of solar collectors employed. The first is line focus technologies, which focus solar energy along a collector’s focal length, such as a parabolic trough and the linear Fresnel reflector. The second is point-focus technologies, which focus the heat of the sun on a point using devices like parabolic dishes and solar thermal towers [44,45]. The point focus CSP, such as the power tower and the parabolic dish, can be used in slopped lands. The solar field is made up of an array of mirrors or reflectors that gather and concentrate solar energy onto a receiving tube. The receiver tube absorbs heat from the focused solar radiation using a thermal energy carrier called Heat Transfer Fluid (HTF), which may then be utilized directly or in conjunction with a secondary circuit to produce electricity [46]. The solar field’s size is directly proportional to the power block’s capacity; the solar multiple is the ratio of thermal power generated by the solar field to that needed by the power block at the design point. When estimating the size of the solar field, the TES and solar multiple should be considered. Using a higher solar multiple could result in overdesigning, and using lower solar multiple results in a lower utilization of the TES because the heat produced will be reduced [47]. Therefore, optimization analysis should be done on the solar multiple and the size of TES to achieve the lowest possible LCOE and the highest Capacity Factor for the power plant [48].

The DNI, which impacts the size of the solar field, is an essential factor that must be considered while designing CSP plants. As a result of a smaller solar field being required to run the power block at its rated output due to a greater DNI, the power plant’s LCOE decreases [49]. According to the international energy agency (IEA), CSP developers set a suitable range for the operation of the CSP in areas with annual DNI from 1900 kWh/m2 to 2100 kWh/m2. Below this range of DNI, other solar electric technologies such as photovoltaic, are a competitive advantage to take advantage of both direct and diffuse irradiances. As a result, site selection is crucial to the design. According to Fig. 6, the MENA region, Spain, South Africa, Australia, and the South-West of the United States all displayed the highest DNI values.

Fig 6

  1. Download : Download high-res image (489KB)
  2. Download : Download full-size image

Fig. 6. Direct normal irradiation map around the globe. (Source: Solar Atlas).

2.1. Global CSP projects

Several CSP projects have been deployed across the world, there are more than 143 projects worldwide, with 114 in operation, 20 now non-operational or decommissioned, and 9 under construction to begin operations in 2022 and 2023 were summarized here in this study. Spain, the United States, and China are the leading countries in the construction and the operation of CSP plants; Spain has the most installed capacity with more than 2.3 GW and 51 projects built around the country, all of which are operational. Since the beginning of CSP, the US has implemented more than 26 projects around the country, although only 1.5 GW of capacity is operational. Meanwhile, China has 596 MW of installed capacity, and several projects are still under construction. Fig. 7 compares the installed capacity for each country worldwide, including all power plants currently under construction. Table 1 shows all the projects around the world. (This information was obtained from National Renewable Energy Laboratory “NREL” official website). Also, the data given in the figure are based on this data.

Fig 7

  1. Download : Download high-res image (157KB)
  2. Download : Download full-size image

Fig. 7. Global installed CSP capacity (MW) distribution.

Table 1. CSP projects worldwide. (Source: Solarpaces, the National Renewable Energy Laboratory).

Power plant Location Lat. Long. Solar irradiation (kWh/m2.year) Capacity (MW) Solar field Area (m2) Technology Status Start year
ISCC Hassi R’mel Algeria 33.12 3.35 2159 20 183,860 Parabolic Trough Operational 2011
Jemalong Australia −33.4 148.1 1.1 15,000 Power Tower Operational 2017
Lake Cargelligo Australia −33.31 146.4 3 6080 Power Tower Non-Operational 2011
Liddell Australia −32.37 150.9 3 18,490 Linear Fresnel Non-Operational 2012
Solar Heat and Power Liddell Australia −32.37 150.9 1 Linear Fresnel Non-Operational 2004
Sundrop Australia −32.59 137.8 1.5 51,505 Power Tower Operational 2016
City of Medicine Hat ISCC Canada 50.04 −110.7 1.1 5248 Parabolic Trough Operational 2014
Atacama I / Cerro Dominador Chile −22.77 −69.47 3186 110 1484,000 Power Tower Operational 2021
Badaling Dahan China 40.38 115.93 1290 1 10,000 Power Tower Operational 2012
CEEC Hami China 43.61 94.95 1789 50 696,751 Power Tower Operational 2019
CEIC Dunhuang China 1649 100 Linear Fresnel Under Construction 2023
CGN Delingha China 37.35 97.27 1950 50 620,000 Parabolic Trough Operational 2018
CSNP Urat China 41.50 108.58 2170 100 1150,000 Parabolic Trough Operational 2020
Huaqiang TeraSolar China 41.21 114.5 15 170,000 Linear Fresnel Operational 2018
Huidong China 110 Beam-Down Tower Under Construction 2023
Jinta Zhongguang China 100 Power Tower Under Construction 2023
Lanzhou Dacheng Dunhuang China 40.08 94.42 1786 10 Linear Fresnel Operational 2016
Lanzhou Dacheng Dunhuang China 40.08 94.42 1649 50 1270,000 Linear Fresnel Operational 2019
LuNeng Haixi China 36.39 95.22 1945 50 610,000 Power Tower Operational 2019
Power China Qinghai Gonghe China 36.10 100.6 1883 50 516,000 Power Tower Operational 2020
Shouhang Dunhuang Phase I China 40.08 94.43 1777 10 175,375 Power Tower Operational 2016
Shouhang Dunhuang Phase II China 40.06 94.42 1777 100 1400,000 Power Tower Operational 2018
SUPCON Delingha China 37.36 97.29 2043 10 63,000 Power Tower Operational 2013
SUPCON Delingha China 37.36 97.29 2043 50 542,700 Power Tower Operational 2018
Yumen Xinneng / Xinchen China 40.33 97.27 1641 50 208,240 Beam-Down Tower Operational 2021
Aalborg CSP-Brønderslev Denmark 57.25 9.98 1025 5.5 26,929 Parabolic Trough Operational 2016
ISCC Kuraymat Egypt 29.27 31.24 2154 20 130,800 Parabolic Trough Operational 2011
Augustin France 42.50 1.97 1800 0.3 400 Linear Fresnel Operational 2012
eLLO France 42.46 2.06 1930 9 153,000 Linear Fresnel Operational 2019
Jülich Germany 50.91 6.38 902 1.5 17,650 Power Tower Operational 2008
ACME India 28.18 73.24 2.5 16,222 Power Tower Operational 2011
Dadri ISCC India 28.57 77.63 1223 14 33,000 Linear Fresnel Operational 2019
Dhursar India 26.78 72.00 1742 125 Linear Fresnel Operational 2014
Godawari India 27.60 72.22 1667 50 392,400 Parabolic Trough Operational 2013
KVK Energy Solar India 27.38 71.77 1940 100 Parabolic Trough Non-Operational 2013
Megha India 14.94 77.68 1476 50 366,240 Parabolic Trough Operational 2014
National Solar Thermal Power Facility India 28.42 77.15 1 8000 Parabolic Trough Operational 2012
Ashalim Plot A Israel 30.96 34.68 2393 110 4000,000 Parabolic Trough Operational 2019
Ashalim Plot B Israel 30.96 34.72 2393 121 1052,480 Power Tower Operational 2019
SEDC Israel 6 Power Tower Operational 2006
Archimede Italy 37.13 15.21 1936 4.7 31,860 Parabolic Trough Operational 2010
ASE Demo Plant Italy 42.73 12.52 1527 0.4 3398 Parabolic Trough Operational 2013
Partanna MS-LFR Italy 1800 4.26 83,200 Linear Fresnel Under Construction 2022
Rende Italy 39.37 16.24 1 9780 Linear Fresnel Operational 2014
Stromboli Italy 1800 4 Linear Fresnel Under Construction
Shagaya Kuwait 29.13 47.01 50 Parabolic Trough Operational 2019
Agua Prieta II Mexico 31.32 −109.5 12 85,000 Parabolic Trough Operational 2017
Airlight Energy Ait-Baha Pilot Plant Morocco 30.21 −9.14 2200 3 6159 Parabolic Trough Operational 2014
ISCC Ain Beni Mathar Morocco 34.06 −2.1 2072 20 183,120 Parabolic Trough Operational 2011
NOOR I Morocco 30.99 −6.86 2497 160 1308,000 Parabolic Trough Operational 2015
NOOR II Morocco 2503 200 1779,900 Parabolic Trough Operational 2018
NOOR III Morocco 31.06 −6.87 2508 150 1312,000 Power Tower Operational 2018
ISCC Duba 1 Saudi Arabia 27.74 35.45 2469 43 Parabolic Trough Under Construction 2023
ISCC Waad Al Shamal Saudi Arabia 31.63 38.87 2521 50 Parabolic Trough Operational 2018
Ilanga I South Africa −28.49 21.54 2937 100 869,800 Parabolic Trough Operational 2018
Kathu Solar Park South Africa −27.73 23.06 2830 100 Parabolic Trough Operational 2019
Bokpoort South Africa −28.74 21.99 2949 50 588,600 Parabolic Trough Operational 2016
KaXu Solar One South Africa −28.90 19.62 2963 100 800,000 Parabolic Trough Operational 2015
Khi Solar One South Africa −28.53 21.07 2952 50 576,800 Power Tower Operational 2016
Redstone South Africa 100 850,000 Power Tower Under Construction 2023
Xina Solar One South Africa −28.89 19.59 2960 100 Parabolic Trough Operational 2018
Andasol 1 Spain 37.23 −3.07 2260 50 510,120 Parabolic Trough Operational 2008
Andasol 2 Spain 37.23 −3.07 2260 50 510,120 Parabolic Trough Operational 2009
Andasol 3 Spain 37.22 −3.06 2260 50 510,120 Parabolic Trough Operational 2011
Arcosol 50 Spain 36.66 −5.83 2007 50 510,120 Parabolic Trough Operational 2011
Arenales Spain 37.16 −5.54 2064 50 510,120 Parabolic Trough Operational 2013
Aste 1A Spain 39.17 −3.23 2104 50 510,120 Parabolic Trough Operational 2012
Aste 1B Spain 39.17 −3.26 2104 50 510,120 Parabolic Trough Operational 2012
Astexol II Spain 38.81 −7.05 2055 50 510,120 Parabolic Trough Operational 2012
Borges Termosolar Spain 41.52 0.8 1878 22.5 183,120 Parabolic Trough Operational 2012
Casablanca Spain 39.23 −5.31 2064 50 510,120 Parabolic Trough Operational 2013
CRS Spain 5 10,560 Power Tower Operational 2012
Enerstar Spain 38.72 −0.92 1992 50 339,506 Parabolic Trough Operational 2013
Extresol 1 Spain 38.65 −6.73 2096 50 510,120 Parabolic Trough Operational 2010
Extresol 2 Spain 38.65 −6.73 2096 50 510,120 Parabolic Trough Operational 2010
Extresol 3 Spain 38.65 −6.73 2096 50 510,120 Parabolic Trough Operational 2012
Gemasolar Spain 37.56 −5.33 2072 20 304,750 Power Tower Operational 2011
Guzmán Spain 37.15 −5.27 2064 50 310,406 Parabolic Trough Operational 2012
Helioenergy 1 Spain 37.58 −5.11 2159 50 300,000 Parabolic Trough Operational 2011
Helioenergy 2 Spain 37.58 −5.11 2068 50 300,000 Parabolic Trough Operational 2012
Helios I Spain 39.24 −3.47 2092 50 300,000 Parabolic Trough Operational 2012
Helios II Spain 39.24 −3.47 2092 50 300,000 Parabolic Trough Operational 2012
Ibersol Ciudad Real Spain 38.64 −3.97 2042 50 287,760 Parabolic Trough Operational 2009
La Africana Spain 37.75 −5.05 2062 50 550,000 Parabolic Trough Operational 2012
La Dehesa Spain 38.95 −6.46 2069 50 552,750 Parabolic Trough Operational 2011
La Florida Spain 38.81 −6.82 2086 50 552,750 Parabolic Trough Operational 2010
La Risca Spain 38.82 −6.82 2085 50 352,854 Parabolic Trough Operational 2009
Lebrija 1 Spain 37.00 −6.04 2065 50 412,020 Parabolic Trough Operational 2011
Majadas I Spain 39.96 −5.74 2086 50 372,240 Parabolic Trough Operational 2010
Manchasol 1 Spain 39.18 −3.30 2107 50 510,120 Parabolic Trough Operational 2011
Manchasol 2 Spain 39.18 −3.31 2107 50 510,120 Parabolic Trough Operational 2011
Morón Spain 37.14 −5.47 2068 50 380,000 Parabolic Trough Operational 2012
Olivenza 1 Spain 38.81 −7.05 2053 50 402,210 Parabolic Trough Operational 2012
Orellana Spain 38.99 −5.54 2074 50 405,500 Parabolic Trough Operational 2012
Palma del Río I Spain 37.64 −5.25 2064 50 372,240 Parabolic Trough Operational 2011
Palma del Río II Spain 37.64 −5.25 2064 50 372,240 Parabolic Trough Operational 2010
Planta Solar 10 Spain 37.44 −6.25 2076 11 75,000 Power Tower Operational 2007
Planta Solar 20 Spain 37.442 −6.25 2076 20 150,000 Power Tower Operational 2009
Puerto Errado 1 Spain 38.27 −1.6 1996 1.4 48,562* Linear Fresnel Operational 2009
Puerto Errado 2 Spain 38.27 −1.6 1996 30 302,000 Linear Fresnel Operational 2012
Solaben 1 Spain 39.22 −5.39 2076 50 300,000 Parabolic Trough Operational 2013
Solaben 2 Spain 39.22 −5.39 2076 50 300,000 Parabolic Trough Operational 2012
Solaben 3 Spain 39.22 −5.39 2076 50 300,000 Parabolic Trough Operational 2012
Solaben 6 Spain 39.22 −5.39 2076 50 300,000 Parabolic Trough Operational 2013
Solacor 1 Spain 37.95 −4.49 2042 50 300,000 Parabolic Trough Operational 2012
Solacor 2 Spain 37.95 −4.49 2042 50 300,000 Parabolic Trough Operational 2012
Solnova 1 Spain 37.44 −6.25 2076 50 300,000 Parabolic Trough Operational 2009
Solnova 3 Spain 37.44 −6.25 2076 50 300,000 Parabolic Trough Operational 2009
Solnova 4 Spain 37.44 −6.25 2076 50 300,000 Parabolic Trough Operational 2009
Termesol 50 Spain 36.66 −5.84 2007 50 510,120 Parabolic Trough Operational 2011
Termesol 1 Spain 39.19 −5.57 2077 50 523,200 Parabolic Trough Operational 2013
Termesol 2 Spain 39.19 −5.57 2077 50 523,200 Parabolic Trough Operational 2013
Thai Solar Energy 1 Thailand 14.33 99.70 5 45,000 Parabolic Trough Operational 2012
Greenway CSP Turkey 36.86 34.61 1.4 Power Tower Operational 2012
Noor Energy 1 United Arab Emirates 24.76 55.36 1967 100 Power Tower Under Construction 2022
Noor Energy 1 United Arab Emirates 24.76 55.36 1967 600 Parabolic Trough Under Construction 2022
Shams 1 United Arab Emirates 23.57 53.71 2019 100 627,840 Parabolic Trough Operational 2013
Crescent Dunes United States 38.23 −117.3 2734 110 1197,148 Power Tower Operational 2015
Genesis United States 33.66 −114.9 2676 250 1928,320 Parabolic Trough Operational 2014
Holaniku United States 19.71 −156.0 2 15,378 Parabolic Trough Non-Operational 2009
Ivanpah United States 35.55 −115.4 2768 377 2600,000 Power Tower Operational 2014
Kimberlina United States 35.56 −119.1 5 25,988 Linear Fresnel Non-Operational 2008
Maricopa United States 33.55 −112.2 1.5 Dish Non-Operational 2010
Martin Next Generation United States 27.05 −80.56 1799 75 464,908 Parabolic Trough Operational 2010
Mojave United States 35.01 −117.3 2888 280 1559,347 Parabolic Trough Operational 2014
National Solar Thermal Test Facility United States 5 Power Tower Operational 1976
Nevada Solar One United States 35.8 −114.9 2625 72 357,200 Parabolic Trough Operational 2007
Saguaro United States 32.54 −111.2 1 10,340 Parabolic Trough Non-Operational 2006
Sierra SunTower United States 34.73 −118.1 5 27,670 Power Tower Non-Operational
Solana United States 32.91 −112.9 2784 250 2200,000 Parabolic Trough Operational 2013
Solar Electric Generating Station I United States 34.86 −116.8 2885 13.8 82,960 Parabolic Trough Decommissioned 1984
Solar Electric Generating Station II United States 34.86 −116.8 2885 30 190,338 Parabolic Trough Decommissioned 1985
Solar Electric Generating Station III United States 35.01 −117.5 2987 30 230,300 Parabolic Trough Decommissioned 1985
Solar Electric Generating Station IV United States 35.01 −117.5 2987 30 230,300 Parabolic Trough Decommissioned 1985
Solar Electric Generating Station IX United States 35.03 −117.3 2893 80 483,960 Parabolic Trough Operational 1990
Solar Electric Generating Station V United States 35.01 −117.5 2987 30 250,500 Parabolic Trough Decommissioned 1989
Solar Electric Generating Station VI United States 35.01 −117.5 2987 30 188,000 Parabolic Trough Decommissioned 1989
Solar Electric Generating Station VII United States 35.01 −117.5 2987 30 194,280 Parabolic Trough Decommissioned 1989
Solar Electric Generating Station VIII United States 35.03 −117.3 2893 80 464,340 Parabolic Trough Decommissioned 1989
Solar One United States 34.87 −116.8 2885 10 72,650 Power Tower Decommissioned 1982
Solar Two United States 34.87 −116.8 2885 10 Power Tower Decommissioned 1995
Stillwater GeoSolar United States 39.54 −118.5 2 Parabolic Trough Operational 2015
Tooele Army Depot United States 40.50 −112.3 1.5 Dish Non-Operational

Based on the data from Table 1, the most utilized technology is parabolic trough collectors (PTC), with 91 projects, followed by solar thermal towers with 34 projects, linear Fresnel reflectors with 16 projects, and just two dish projects, both of which are decommissioned. Around 75% of installed capacity utilized the PTC technology. Furthermore, the linear Fresnel reflectors technology was found to have the largest land usage factor among the other technologies. However, the needed solar field area per 1 MW of capacity was found to be roughly 11,000 m2 for both linear Fresnel and Power Tower.

Fig. 8 depicts the number of projects completed each year since 2004. It can be seen that in 2012, more than 25 CSP projects were installed. While the Covid-19 pandemic may have had a detrimental impact on the deployment of CSP plants, with around 7 projects completed during that period (2020 to 2022). However, this sector is expected to recover, with around 5 projects with a combined capacity of more than 1.1 GW set to begin operations within the next few months. Fig. 9 displays the total installed capacity for each technology for 141 different power plants. The figure shows a high potential of the use of parabolic trough CSP compared to the other systems.

Fig 8

  1. Download : Download high-res image (203KB)
  2. Download : Download full-size image

Fig. 8. Number of installed CSP projects each year since 2004.

Fig 9

  1. Download : Download high-res image (107KB)
  2. Download : Download full-size image

Fig. 9. Total installed capacity for each CSP technology.

Further, Fig. 10, Fig. 11 compare the land use factor for 81 power plants and the average solar field area required in m2 per 1 MW of capacity for 110 power plants; respectively. The lowest land use factor is attained for a power tower central receiver with a ratio of around 18.6% followed by the parabolic trough CSP with a percent around 25%. The highest land use factor is attained by the LFL CSP with a percent around 45.5%. It is also can be concluded that the CSP with a parabolic trough needs around 8504 m2 for every 1 MW only for the solar field.

Fig 10

  1. Download : Download high-res image (269KB)
  2. Download : Download full-size image

Fig. 10. Average land use factor comparison between the different technologies.

Fig 11

  1. Download : Download high-res image (242KB)
  2. Download : Download full-size image

Fig. 11. Average solar field required in (m2) for 1 MW of capacity for each technology.

According to Trieb et al. [50] in 2009, the land usage factor ranges for linear Fresnel, parabolic trough, and power tower are (60 to 80%), (25 to 40%), and (20 to 25%), respectively. However, according to the NREL statistics in Table 1, all linear Fresnel projects were below that range, and just 23.5% of power tower projects were within it. Meanwhile, 60% of parabolic trough-based projects were determined to be within the range. This difference may be result of the progress of technology in recent years. The total solar to electricity efficiency of the parabolic trough, LFL, and central receiver ranges from 11∼16%, 8∼12%, and 12∼16%, respectively.

2.2. Heat transfer fluids (HTF)

To collect the heat from the solar field, heat transfer fluid (HTF) should be used. The HTF significantly influence the effectiveness and performance of CSP. A CSP plant necessitates a significant amount of HTF to run, thus, it’s important to keep HTF costs down while increasing its efficiency. The HTF can transfer the heat to the power block or the TES tanks. A HTF should have the following desired properties: low melting point, high boiling point, thermal stability, low vapor pressure (1 atm) at high temperature, low corrosion with metal alloys used to hold the HTF, low viscosity, high thermal conductivity, high heat capacity for energy storage, and inexpensive [51,52].

Heat transfer fluids utilized in CSP technologies include air, water, molten salts, glycol-based, glycerol-based, and synthetic oils. These days, air and water are rarely utilized since heating air causes it to expand in volume, requiring a larger heat exchanger to be constructed for effective heat transmission, which raises the investment cost. Water oxidizes fast at high temperatures, which can cause the absorber tube materials to react and produce corrosion in the interior regions of the tube. The additional fluids available are employed at different working temperatures. Fluids based on glycol are utilized for applications below 175 °C, whereas synthetic fluids are used for applications beyond 400 °C [53]. Organic materials are also employed as HTFs. In commercial CSP systems, for example, biphenyl/diphenyl oxide is often employed. Therminol and Dowtherm fluids are commercially available Biphenyl/Diphenyl oxide HTFs. There are now eight solar thermal plants in the world that use Biphenyl/Diphenyl oxide, all of which are situated in Spain. This Biphenyl/Diphenyl oxide has a recommended operating temperature range of 12–393 °C.

In large CSP plants, air is a very infrequent HTF. Only one commercial-scale system has been developed, a 1.5 MWe solar tower pre-commercial plant in Jülich, Germany, that commenced operating in 2009. Air offers superior flow qualities inside CSP pipes when compared to other liquid HTFs such as molten salts or liquid metals. Even while air has a lower thermal conductivity than molten salts or liquid metals, its greater flow feature provides an added benefit for efficient heat transmission [54].

Water steam-based single-fluid solar thermal systems, such as direct steam generation (DSG) parabolic troughs, have been researched and developed since the 1980s, when alternatives to oil-based technologies were investigated [55]. If the HTF is not water/steam, the thermal energy gathered at the receiver is conveyed by the non-water based HTF to the steam generator and then transferred to the working fluid (often water/steam). Working fluid then transports the energy to the turbine, which generates electricity. Feldhoff et al. [56] demonstrated that direct steam generation systems using water/steam as the only fluid had an 11% lower Levelized cost of energy (LCOE) than systems using oil-based HTFs. Water steam is utilized as both HTF and working fluid at the world’s most recent and biggest CSP plant, the Ivanpah solar power plant, which started operating in 2014. There are already seven operational CSP plants worldwide that use water/steam as a single fluid. Four of the factories are in Spain, with the other three in the United States [52]. The main concern with the water/steam HTF is a lack of water in arid locations. These CSP plants are generally located in deserts with enormous land areas and high direct solar radiation intensity [57].

The thermal stability of molten salts at high temperatures (usually > 500 °C) makes them good HTFs. Molten salts also exhibit high-temperature characteristics similar to water, such as similar viscosity and low vapor pressure [58]. Molten-salt-based HTFs are widely employed in current CSP systems, with the first molten-salt power tower systems being installed in 1984. HTFs in CSP applications have been studied and utilized as mineral, silicone, and synthetic oils. Because these oils are only thermally stable up to 400 °C, they are not often employed in high-temperature and highly efficient solar thermal systems [59]. Another concern with these thermal oils is their high price. Some heat transfer fluids, including some that have been employed in the past, are included in Table 2. This table shows different types of HTF used in CSP. Also, the operating temperature range, density, and viscosity are displayed at a temperature of 300 °C. However, Fig. 12, Fig. 13, Fig. 14, Fig. 15 presents the variation of thermophysical properties of these different HTFs with the temperature. Generally, it is noticed that increasing the temperature of all the used HTF decreases the density, thermal conductivity, and viscosity. While increasing the temperature increases the HTF-specific heat capacity. According to the figures, Therminol 72 has the maximum density in the temperature range of 0 – 275 °C. Dowtherm G, on the other hand, has the maximum density above 275 °C. Therminol 12-D has the highest specific heat capacity in the temperature range 0 – 250 °C, Therminol XP has the highest in temperature range 250 – 330 °C, and Therminol VP-3 has the highest in temperature range 330 – 360 °C. Among the HTFs, Therminol 72 has the maximum thermal conductivity. Therminol 66 has the highest viscosity, whereas Therminol LT has the lowest.

Table 2. Some of heat transfer fluids (HTF) used in CSP.

Heat transfer fluid Empty Cell Composition (%) Operating temperature Range (  °C) Viscosity at 300 °C (mPa.s) Density at 300 °C (kg/m3) Heat capacity at 300 °C (kJ/kg.K) Reference
Empty Cell Ca(NO3)2 NaNO2 NaNO3 KNO3
Hitec 7 40 53 (142 – 535) 3.16 1640 1.56 [60]
Hitec XL 48 7 45 (120 – 500) 6.37 1992 1.44 [60]
Solar Salt 60 40 (220 – 600) 3.26 1899 1.49 [60]
Therminol VP-1 Diphenyl biphenyl oxide (12 – 400) 0.2 815 2.31 [60,61]
LiNO3 Mixture (550 – 120) [60]
Therminol 62 Isopropyl biphenyl mixture (−22 – 345) 0.239 730 2.53 [62]
Therminol 66 Modified terphenyl (−3 – 345) 0.413 809 2.57 [63]
Therminol XP White mineral oil (−20 – 315) 0.375 690 2.95 [64]
Therminol VP-3 Phenylcyclohexane + bicyclohexyl (2 – 330) 0.199 687 2.747 [65]
Therminol LT Alkyl-substituted aromatic (−75 – 315) 0.114 583 2.88 [66]
Therminol D-12 Synthetic hydrocarbons (−94 – 230) 0.135* 562* 3.08* [67]
Therminol ADX-10 Synthetic aromatic hydrocarbon mixture (−56 – 250) 0.275* 686* 2.72* [68]
Therminol 54 Synthetic hydrocarbon mixture (−28 – 280) 0.33 672 2.9 [69]
Therminol 55 Synthetic hydrocarbon mixture (−28 – 300) 0.334 672 2.9 [70]
Therminol SP Synthetic hydrocarbon mixture (−28 – 300) 0.334 672 2.9 [71]
Therminol 59 Alkyl-substituted aromatic (−49 – 315) 0.251 755 2.62 [72]
Therminol 68 Mixture of synthetic aromatics (−26 – 360) 0.35 826 2.527 [73]
Therminol 72 Mixture of synthetic aromatics (−14 – 380) 0.23 825 2.311 [74]
Therminol 75 Terphenyl/quaterpheny (80 – 385) 0.368 872 2.28 [75]
DOWTHER A Diphenyl Oxide/Biphenyl Blend (15 – 400) 0.2 801.3 2.373 [76]
DOWTHER Q Mixture of diphenylethane and alkylated aromatics (−35 – 330) [77]
DOWTHER G Mixture of di- and tri-aryl compounds (−6 – 360) 0.3 833.8 2.507 [78]
DOWTHER RP Diaryl alky (0 – 350) 0.38 817.4 2.483 [79]

*Values were Taken at 250 °C.

Fig 12

  1. Download : Download high-res image (557KB)
  2. Download : Download full-size image

Fig. 12. Density variation of different HTF with the temperature.

Fig 13

  1. Download : Download high-res image (658KB)
  2. Download : Download full-size image

Fig. 13. Specific heat capacity variation of different HTF with the temperature.

Fig 14

  1. Download : Download high-res image (547KB)
  2. Download : Download full-size image

Fig. 14. Thermal conductivity of different HTF with the temperature.

Fig 15

  1. Download : Download high-res image (589KB)
  2. Download : Download full-size image

Fig. 15. Viscosity of different HTF with the temperature.

2.3. Energy storage systems (ESS)

Several methods can be used to store energy. Often, these technologies are grouped based on how long the energy will be retained. The two most popular ways to categorize energy storage systems are by the type of energy storage and the discharge duration. Based on the discharge time, energy storage techniques are classified as short-term (seconds or minutes), medium-term (minutes or hours), and long-term (hours to days). The type of transformed energy heavily influences the categorization of energy storage methods. As indicated in Fig. 16, Mechanical, electrochemical, thermal, electrical and chemical energy storage are the five basic categories that they may be divided into [80]. When needed, these technologies convert energy into a different form for storage before returning it to its original form [81].

Fig 16

  1. Download : Download high-res image (357KB)
  2. Download : Download full-size image

Fig. 16. Classification of energy storage systems.

The operating principle of CAES is quite straightforward. The storage is charged by converting electrical energy through electrically driven compressors into the potential energy of pressed air. The compressed air is released when needed to continue generating power by allowing air to expand through an air turbine. It now ranks second in bulk energy storage behind PHS. To provide continuous load reaction and peak generation, CAES is used as a source of flexible supply at utility sizes between 10 MW and 100 MW. For almost 40 years, CAES, with an estimated efficiency of 70% performed successfully [82,83]. The PHS uses an electric pump that runs on electricity during off-peak hours to transfer water from a lower tank to a higher tank, dam, or reservoir, storing this water at a high level in form of potential energy. The turnaround converts the potential energy into mechanical energy, which is then converted to electrical energy, when there is high demand. PHS has a 70–80% roundtrip efficiency. The expected lifespan of PHES is between 40 and 60 years. It is the most popular and reasonably priced choice for large-scale energy storage [81,84]. A flywheel functions as a mechanical battery by storing kinetic energy in the manner of rotational mass. Rotor is often fitted in an evacuated cylinder, allowing it to use renewable or off-peak electricity to accelerate at very high speeds and store it as rotational energy. When storing energy, the device acts as a motor and a generator when discharging. Flywheels have a high energy efficiency of higher than 85%. Flywheels are ideal for switching between medium and high powers (kW-MW) within very short periods of time (seconds) [81].

Gravity Storage is a technique that permits huge amounts of power to be stored for 6–14 h and then released. The fundamental concept relies on the hydraulic lifting of a large rock mass. Electrical pumps, used nowadays in hydro-power plants, are used to flow water beneath a moving rock piston, to lift up the rock mass. When the supply of renewable energy is insufficient, the water, which is under extreme pressure from the rock mass, is directed to a turbine, as in standard hydroelectric facilities, and employs a generator to create power. The range of energy storage options is 1 to 10 GWh, which is comparable to large Hydro-power dams. [85]. Battery energy storage system (BESS) is a cutting-edge technology solution that allows energy to be stored in a variety of ways until it is needed. Rechargeable batteries are utilized in lithium ion battery storage systems in particular to store energy produced by solar panels or provided by the grid and then make it available when needed. The benefits of battery energy storage include increased renewable energy production, cost savings, and sustainability due to reduced consumption. The typical lifespan of energy battery storage devices is 5 – 15 years [86].

The same basic equations that govern capacitors are used in supercapacitors, which are energy storage devices. However, in order to accumulate large amounts of charge carriers and capacitances, supercapacitors commonly use porous carbon or electrodes with larger surface areas and thinner dielectrics. This type of system offers a number of advantages, including exceptionally high capacitance characteristics, on the scale of thousands of farads, extended cycle life, low internal resistance, rapid charging and discharging, remarkable reversibility, great low-temperature performance, no destructive material, cheaper cost per cycle, and high cycle efficiency (up to 95%). [87]. The electrodynamic concept underpins the Superconducting Magnetic Energy Storage (SMES) technology. When direct current flows through a superconducting coil that has been cryogenically cooled to an extremely low temperature, an energy-storing magnetic field is formed. In most cases, niobium-titanium is used to make the conductor, while fluid helium at 4.2 K or super liquid helium at 1.8 K is used as the coolant [81]. The immediate availability of the required electricity is one of the key advantages of SMES. The framework’s high overall round-trip efficiency (between 85% and 90%) and the potent yield that may be produced in a short amount of time are further characteristics [88].

An electrolyzer, a hydrogen storage tank, and a fuel cell are typical components of a hydrogen storage system. An electrolyzer is a device that employs electricity to electrochemically transform water into hydrogen and oxygen. In order to create electricity, both gasses must enter a fuel cell. There, they go through an electrochemical process that is the opposite of water splitting: hydrogen and oxygen react to create water, while heat is generated to produce electricity [89,90]. Hydrogen is produced by electrolyzing water using off-peak electricity for use in energy storage. hydrogen may also be stored in different viable options such as, liquefied gas, metal hydrides, compressed gas or carbon nanostructures [81]. There are three types of TES systems, only one of which is commercially available in the electricity sector. Sensible heat storage is significantly simpler and more affordable than the alternatives. Thermal-chemical storage systems and latent energy storage are expensive and still primarily experimental technologies. The most often used TES in the energy production sector is sensible heat storage. In a sensible heat TES system, energy is stored by heating or cooling a solid or liquid storage medium, such as molten salt, sand, water or rocks. Sensible heat storage is widely employed in CSP plants, where the use of TES enables a project to produce energy far after the sun sets. In most CSP plants utilizing TES, molten salts, which can withstand extremely high temperatures, are the chosen medium. Despite being used less often in the energy production sector, latent heat storage has shown promise in a number of recent technologies. A change in the storage medium’s condition, such as from solid to liquid, is necessary for latent heat storage. Phase change materials (PCMs) are a common name for latent heat storage media. Thermo-chemical storage (TCS), as the name implies, employs chemical processes to store energy. Compared to PCMs, TCS systems have an even higher energy density [48,91].

Each energy storage system has distinctive features and characteristics that, in certain cases, make them stand out from one another. It is feasible to choose the best appropriate energy storage technology for a specific situation using these traits and attributes. On the basis of the following technological features, Table 3 compares the main categories of energy storage systems.

Table 3. Technical parameter comparison between the different energy storage systems [92].

Technology Power rating (MW) LCOE ($/kWh) Lifetime (Years) Cycle efficiency (%)
PHS 30 – 5000 5 – 100 40 – 60 70 – 87
CAES 110 – 1000 2 – 120 20 – 40 42 – 54
TES 0.1 – 300 3 – 60 20 – 30 30 – 60
Li-ion 0 – 100 600 – 3800 14 – 16 75 – 97
Lead Acid 0 – 40 50 – 400 5 – 15 63 – 90
Fly Wheels 0.25 – 20 1000 – 14,000 15 – 20 90 – 95
Supercapacitors 0 – 0.3 300 – 2000 10 – 30 84 – 97
SMES 0.1 – 10 500 – 72,000 20 – 30 95 – 98
Fuel Cells < 58.5 2 – 15 ∼ 20 20 – 66

Although TES has one of the lowest cycle efficiencies when compared to other technologies, according to Table 3, it has the a low LCOE among the other technologies with a very long lifetime. The effects of adding TES on the LCOE of various renewable energy systems and hybrid renewable energy systems will be compared with other solutions in the following sections.

2.4. Thermal energy storage (TES) systems for CSP

Currently, two TES commercialized technologies are used in CSP projects around the world; molten salts storage tanks and steam accumulators. Steam accumulation tanks are typically cylindrical with elliptical ends made of boiler plates. One of the primary benefits is that the storage fluid is water, which eliminates price uncertainty in the storage medium. Because of their short reaction times and high discharge rates, steam accumulators are a proven choice for compensating transients and mid-term storage to match supply/demand curves when there is no radiation. Steam accumulation is one of the most successful methods of TES. However, the steam accumulator idea is restricted by a poor connection between volume and stored energy; also, its discharge process exhibits a drop in pressure, failing to achieve nominal conditions in the turbine. There are just two commercial tower plants in existence that use steam accumulator TES; PS10 (with four steam accumulator tanks) and PS20, both situated in Spain [93].

There are two types of molten salt storage tanks, direct and indirect; in the direct TES the salt serves as both the HTF and storage medium in the system. The Solar Two Project at Sandia National Laboratories, which was completed in 1996 with a tower power plant, presented the first major two-tank molten salt storage system. A heat exchanger decouples the thermal storage from the solar receiver’s HTF loop in an indirect storage system. Since 2009, the solar thermal power plant Andasol 1 has run the earliest commercial system with indirect TES. However, compared to tanks used in two-tank thermal storage systems, the thermocline storage system only uses one tank. The storage tank depends on the buoyancy phenomenon to maintain thermal stratification since the number of tanks has been reduced to one, containing both hot and cold fluid. The filler material also functions as a porous medium flow distributor, reducing unwanted secondary velocities that may otherwise de-stratify the hot and cold HTF zones of the tank [94].

On the same side, PCM storage is completely passive, which means that the storage medium remains stationary throughout charge and discharge. Heat transmission into the PCM is facilitated by the HTF being pushed through a tube registry inserted in the PCM. Currently, it is expected that these tube registries consist of tiny, vertically oriented heat exchangers arranged in groups that are connected in series and parallel. In order to obtain the desired flow rates, output temperatures, and overall performance, several heat exchangers are organized in parallel and series. The series number is based on the needed effective tube length, and the parallel number is based on the required effective tube number. Multiple PCMs must be arranged in sequence of melting temperature to step the HTF temperature to the correct level in order to satisfy the requisite output temperatures. Each PCM with a distinct melting temperature is assigned to its own bucket. These buckets are then arranged in succession and referred to as a cascade [95].

TES systems can increase the efficiency with which solar thermal energy is converted into electricity. They provide effective heat storage throughout the day so that power generation can continue at night. It has been found that integrating a TES system with a CSP plant increases the power plant’s capacity factor by more than 20% and decreases the LCOE by around 6% by increasing electricity production [96]. H. Mahon et al. [27] conducted the most recent review on thermal energy storage systems. The researchers’ goal was to identify some of the development challenges currently faced by the four seasonal thermal energy storage options—tank, pit, borehole, and aquifer—and then some of the work being done to overcome these challenges to enable wider adoption throughout energy systems.

The solar multiple is the ratio of the thermal power generated by the solar field at the design point to the thermal power required by the power block under nominal conditions. Recent studies investigated the optimum size of both TES and the solar multiple for different CSP plants, and it is the effect on the LCOE. Kuravi et al. [97] investigated the impact of various TES sizes on the LCOE of a CSP plant located in Daggett, California, using System Advisor Model (SAM). It has been found that the LCOE is reduced by 20% when TES size of 16-h is used as shown in Fig. 17 compared with other sizes [97].

Fig 17

  1. Download : Download high-res image (231KB)
  2. Download : Download full-size image

Fig. 17. TES size effect on the LCOE [97].

Similarly, Qoaider et al. [98] al studied the effect of TES size and solar multiple for Andasol 1 CSP plant located in Spain. Fig. 18 illustrates that employing TES in the investigated location with solar multiple greater than 1.5 and the same meteorological conditions is more economically advantageous. On the same side, Praveen et al. [99] proposed a design for a 100 MW parabolic trough-based CSP plant and used SAM for modeling and optimization at two separate sites in Abu Dhabi, United Arab Emirates, and Aswan, Egypt. It has been found that the utilization of thermal energy storage with a suitable size provides higher energy production and lower LCOE as shown in Fig. 19 for both locations. However, because the HTF (used in both the solar field and the TES) requires part of the stored heat to keep the HTF from freezing, oversizing would raise the LCOE and decrease the yearly production.

Fig 18

  1. Download : Download high-res image (234KB)
  2. Download : Download full-size image

Fig. 18. LCOE as function of solar field and thermal energy storage sizes for Andasol 1 CSP plant [98]. (With permission, License Number: 5442930163790).

Fig 19

  1. Download : Download high-res image (528KB)
  2. Download : Download full-size image

Fig. 19. LCOE and the annual energy generation variation with full load hours of TES; (a) Abu Dhabi, (b) Aswan [99].

Based on the data shown in Fig. 17 through 19, it is possible to draw the conclusion that the solar multiple has a considerable impact on the size of the TES, which in turn has an impact on both the LCOE and the energy production of the system. Changing the size of the TES will result in an unstable power plant condition. For instance, increasing the size of TES will require increasing the solar multiple in order to make full use of the TES and vice versa. If the ideal size of the TES is selected as shown in Fig. 19, then adjusting the solar multiple up or down from a certain value will result in an increase in the LCOE and a decrease in the yearly energy production. Therefore, it is important to carry sensitivity analysis when designing both the solar field and TES sizes.

2.5. Water management in CSP

Water availability is a challenge for constructing any thermoelectric power plant, not just CSP, in arid and semi-arid locations with high water demand. CSP facilities require a large amount of water to create energy. This water is used for mirror cleaning, steam creation, and cooling when wet cooling is employed [100]. As a result, the most significant aspect of the requirements that must be improved is wet cooling. Wet cooling takes significantly more water than dry cooling; the Noor 1 plant in Morocco uses around 74% of total water consumption for the wet cooling process as provided by experimental data from the power plant [101]. A. Liqreina et al. [34] compared the Andasol 1 power plant in Spain that uses wet cooling system to the identical but dry-cooled power plant in Jordan, the following results were obtained: the total efficiency of the dry cooled plant in Ma’an is lowered by 3.1%, and the water usage is reduced by 92%. Energy yield improved by 21.8%, while LCOE decreased by 18.8%. The findings of this study show that dry-cooled CSP power plants in locations with considerably high DNI values are an appealing economic and technical alternative to explore in future project development. Ogunmodimu et al. [102] investigated CSP technologies from environmental, social, and operational perspectives. They determined that parabolic trough collectors are one of the most desirable solutions because of their maturity, despite their high water consumption compared to other systems. The authors found that while the parabolic dish concentrator has the lowest LCOE and water consumption, it lacks a wide range of proven applications. Fig. 20 shows a comparison between the different cooling techniques.

Fig 20

  1. Download : Download high-res image (622KB)
  2. Download : Download full-size image

Fig. 20. Characteristics of cooling systems utilized in CSP plants [100].

3. Hybrid renewable energy with CSP

In hybrid systems, both wind turbines and photovoltaics store their energy in the CSP plant’s TES through an electric heater, as shown in Fig. 21, or in a separate energy storage system such as batteries to prevent electricity curtailment practices [103] and dispatch electricity as needed. When there is a deficit in one kind of available renewable energy resources, other technologies, such as geothermal power plants, may operate in parallel with CSP plants to improve performance. The power generation from the PV and wind systems is recovered by an electric heating mechanism to warm the solar salt in the TES as soon as they start operating.  The thermal energy from the CSP system and the electric heating device generated by the power rejection of the PV and wind systems are both stored in the TES. The TES’s capacity might be enhanced in the meantime to store additional thermal energy during severe weather. To satisfy load demand and address the mismatch, the CSP system can dispatchable electricity in a flexible manner. Currently, there are two hybrid PV-CSP projects under construction in China and United Arab Emirates. Table 4 shows some of the specifications of these power plants.

Fig 21

  1. Download : Download high-res image (551KB)
  2. Download : Download full-size image

Fig. 21. Schematic of the PV/Wind/CSP hybrid system [112].

Table 4. Hybrid PV-CSP plants under construction. (Source: NREL).

Parameter CEIC Dunhuang Noor energy 1
Country China United Arab Emirates
Capacity 100 MW (Linear Fresnel) and 600 MW PV 700 MW (Parabolic Trough & Power Tower) and 250 MW PV
Total Construction Cost ($) 4300 million 14,780 million
Status Under Construction Under Construction
Start Year 2023 2022

3.1. Hybrid CSP/Wind, CSP/PV with TES

The 800 MW Midelt CSP project in Morocco is the first hybrid PV-CSP plant to employ an electric heater to store power generated by PV. The electricity generated by PV will be used to heat the molten salt and then stored in the TES. Originally, the project was supposed to incorporate PV with batteries as a backup to meet daytime needs, as well as a CSP plant with thermal storage to meet nighttime demand. Nonetheless, it has been shown that utilizing thermal energy storage for both units can lower the project’s LCOE to 0.07$/kWh. If the energy demand is high in comparison to the available energy storage and primary resources, Ayadi et al. [104] evaluated the hybrid CSP technology as a solar energy configuration that satisfies predictability and dispatchability requirements. This study’s primary goal is to offer a realistic CSP-Wind scenario for the local market and weather in Jordan at the time it is conducted. The results show that hybridization enhances capacity factor of hybrid power plant up to 94% and offers exceptionally cheap LCOE of 0.063 $/kWh lower than standalone CSP plant. After 25 years of operation, the total earnings of the CSP plant with 5 h of energy storage are approximately 4.5 times more than those of the wind plant of the same scale. Similarly, A. Zurita et al. [105] studied different configurations of hybrid CSP/PV and TES system with and without BESS using fixed plane and tracking system for the PV system. It has been found that the lowest achieved LCOE of the hybrid system was found to be 0.0772 $/kWh and 0.0750 kWh for fixed and tracking system respectively without using BESS. However, the integration of the BESS to the hybrid system raised the capacity factor of the system by 7 to 8% approximately, but that resulted in increasing the LCOE as well by 0.012 $/kWh for the hybrid system.

J.A. Aguilar-Jiménez et al. [106] performed a Techno-Economic analysis on a hybrid PV-CSP system for usage as an energy source in isolated microgrids. According to the findings, the LCOE for the PV-CSP hybrid system is just 2% higher than the LCOE for the PV-Battery system. The LCOE would be 3.43% lower if the PV-CSP was employed with a 50% higher energy consumption. Furthermore, if the demand surpasses 500 kW, the PV-LCOE CSP’s would be 26% cheaper. C. A. Pan and F. Dinter [107] presented a hybrid plant that combines PV and central receiver CSP plants. Simulations of solo PV and CSP plants were performed and compared to simulation results of the proposed CSP-PV hybrid plant. According to the findings, increased yearly energy output and capacity factors of up to 90% are possible. Additionally, system size and expenses can be decreased. Allan Starke et al. [108] investigated the feasibility of combining a CSP plant with a PV system by creating two models for hybrid CSP-PV systems for an Atacama Desert location using the Transient System Simulation tool (TRNSYS). It has been discovered that enabling thermal energy to be stored while the PV plant is in operation improves the capacity factor of the power plant, assisting in the achievement of a completely dispatchable solar electricity production system. M. Petrollese and D. Cocco [109] investigated the feasibility of attaining full dispatchability and the best design parameters for a hybrid CSP-PV plant. The findings revealed that hybrid CSP-PV plants become very cost efficient when a constant power production is required for daily time spans greater than roughly 16 h.

3.2. Hybrid CSP/PV/Wind with TES

Chennaif et al. [110] developed a new technique called The Electric System Cascade Extended Analysis (ESCEA) for evaluating the appropriate size of a standalone hybrid power production system that incorporates PV, wind, and CSP combined with simultaneous TES and BESS. The capacity of the various production and storage components of the system, as well as the percentage contribution of each energy source, are determined by the ESCEA algorithm, which offers all feasible alternatives. The algorithm then chooses the optimal option, which has the lowest LCOE. The algorithm was applied in case study in Oujda, Morocco with an electric load of 50 MW. Several configurations were studied including CSP/PV/Wind with both Batteries and TES but with different share percent for each power plant. The algorithm indicated that lowest achievable LCOE was 0.18 $/kWh for hybrid CSP/PV/Wind system with sharing percent of 65.4%, 26.1% and 8.5% respectively, with TES and BESS compared to other 8 different configurations. Meanwhile, the configuration of PV with BESS and Wind with BESS achieved 0.24 $/kWh and 0.40 $/kWh with an increase of 33.3% and 122.2% with 0% Loss of Power Supply Probability (LPSP). Al-Ghussain et al. [111] investigated the techno-economic feasibility of coupling TES with several PV, wind, and CSP configurations in Jordan, and they compared it to scenarios using lithium-ion batteries. The intermittent nature of solar and wind resources was found to be compensated using TES. In comparison to the other scenarios, the addition of TES to the CSP/PV/Wind system produced the lowest LCOE of 0.0485 $/kWh and the highest renewable energy system fraction percentage of 99.35%.

3.3. Hybrid PV/Wind with TES

Similarly, Guo et al. [113] developed a design for a hybrid wind/PV system employing TES to utilize a 100 MW transmission grid in Karachi as shown in Fig. 22, Pakistan using the MOPSO algorithm. They then compared the LCOE findings with those obtained when using BESS in place of TES and without the usage of storage devices. When TES is added to the hybrid system, the findings reveal a minor decrease in LCOE of 0.074% but a considerable increase in power output of 11.37%. Meanwhile, the LCOE significantly increased by 12.79% because of BESS replacing TES. From an economical perspective, He et al. [114] examined four different energy storage technologies (BESS, TES, PHS, and Hydrogen Storage) to be deployed in a hybrid PV/Wind system for a 100 MW demand profile in Karachi, Pakistan. The findings demonstrate that, under the same LPSP (10%), the LCOEs of TES, BES, Hydrogen, and PHS are, in that order, 0.1421 $/kWh, 0.01793 $/kWh, 0.1956 $/kWh, and 0.2196 $/kWh. This proves that TES is also the most economical energy storage solution for variable load profiles. In addition, Y. He et al. [115] suggested a wind/PV hybrid system with TES and investigated the multiple objective capacity optimization issue that incorporates decreasing LCOE. Different optimization techniques were applied, including algorithms (NSGA-III and MOEA/D) and TOPSIS for decision-making. The hybrid system’s lowest attainable LCOE was determined to be 0.1106 $/kWh with an LPSP of 15.3%.

Fig 22

  1. Download : Download high-res image (545KB)
  2. Download : Download full-size image

Fig. 22. Schematic of hybrid wind/PV with TES [113]. (With permission, License Number: 5442930352987).

3.4. Hybrid geothermal/CSP with TES

In their commercial applications, geothermal and concentrating solar power (CSP) technologies commonly employ heat at various temperatures. This makes it possible for geothermal bottoming cycles and solar topping cycles to be hybridized in places where both resources are present as seen in Fig. 23. McTigue et al. [116] presented technical and financial possibilities of solar-powered steam topping cycle added to an underperforming geothermal power plant located in Idaho, United States. The geothermal cycle is brought back to its design position by the waste heat from the topping cycle. This hybrid idea boosts the efficiency and power production of the geothermal plant while making efficient use of the high temperatures that may be produced by concentrating solar fields. The researchers studied the effect of adding TES on the LCOE to the hybrid system or replacing it with equivalent PV with BESS. The results demonstrated a slight increase in the LCOE of 2.4% but with a significant increase in the annual energy production by 20.44%. Meanwhile, the PV with BESS system provided higher LCOE by 46.09% than utilizing the suggested hybrid system with TES. Similarly, McTigue et al. [117] studied hybrid Geothermal/CSP plant for solar heat addition to compensate for the declining in geothermal resources for geothermal plant in California, United States. The results of the hybrid with 3 h and 10 h TES size system were compared to an equivalent PV with BESS. It has been found that it was discovered that the hybrid system with 3 h of storage had a 28% reduced LCOE, while a system with 10 h of storage had a 47% lower LCOE.

Fig 23

  1. Download : Download high-res image (403KB)
  2. Download : Download full-size image

Fig. 23. Schematic of hybrid geothermal-CSP power plant [116]. (With permission, License Number: 5442930488336).

Table 5 shows a list of recent studies that focus on hybrid systems using TES and their LCOE results are included along with the study’s location. The table shows that in Jordan, where both GHI and DNI values are relatively high, it is possible to achieve 0.0485 $/kWh LCOE of hybrid PV/Wind/CSP with TES system, leading to excellent performance for PV and CSP plants and a significant decrease in LCOE [111]. In general, regions with high DNI values, such as the MENA region, Chile, the United States, Australia, and China, may obtain LCOEs of less than 0.1 $/kWh. TES has the lowest LCOE and one of the highest lifespan systems when compared to other energy storage technologies. Additionally, it enables hybrid systems to increase their capacity factor to 90%, which helps to overcome the variability of renewable resources and the intermittency of renewable energy systems generation, resulting in more stable grids and better demand matching.

Table 5. Summary of LCOE results from recent hybrid renewable energy systems research.

Reference System configuration Location LCOE ($/kWh)
[118] PV/CSP with TES Delingha, China 0.1484
PV/Wind/CSP with BESS and TES 0.1964
[119] PV/Wind/CSP with BESS and TES Huade, China 0.0997
Ulan Moron, China 0.1111
[120] PV/Wind/CSP/Diesel Generator with BESS and TES Tabuk, Saudi Arabia 0.0917
PV/Wind/CSP with BESS and TES 0.1557
[117] Geothermal/CSP with TES California, United States 0.081
PV with BESS 0.148
[112] PV/Wind/CSP with TES and PHS China 0.1186
[105] PV/CSP with TES Northern Chile 0.07722
[110] PV/Wind/CSP with TES and BESS Oujda, Morocco 0.1830
CSP with TES 0.1963
PV with BESS 0.2383
Wind with BESS 0.40
[111] PV with TES Jordan 0.0493
PV/Wind with TES 0.0497
PV/CSP with BESS 0.0488
PV/CSP with TES 0.0499
PV/Wind/CSP with TES 0.0485
PV/Wind/CSP with BESS 0.0497
[116] Geothermal/CSP 0.125
Geothermal/CSP with TES 0.128
PV with BESS 0.187
[121] PV/Wind with BESS Australia 0.122 – 0.414
PV/Wind with TES 0.059 – 0.113
[115] PV/Wind with TES Karachi, Pakistan 0.1106
[122] PV/Wind/CSP with TES Zhangjiakou, China 0.2775
[114] PV/Wind with TES Karachi, Pakistan 0.1224
PV/Wind with BESS 0.1812
PV/Wind with PHS 0.2225
PV/Wind with Hydrogen tank 0.1863
[113] PV/Wind Karachi, Pakistan 0.1078
PV/Wind with TES 0.1077
PV/Wind with BESS 0.1215
[104] Wind/CSP with TES Jordan 0.063

4. Current status and future outlook

CSP plants are divided into three generations based on their thermodynamic cycle and cycle efficiency Fig. 24. The first generation of CSP plants use the Rankine cycle, which has a design cycle efficiency of 28–38% and a peak cycle temperature of 240–440 °C, and the PTC, Solar Tower, and LFR are often employed [123]. Because most first generation CSP facilities lacked thermal storage, they could only operate under sunny weather throughout the day. First generation CSPs continue to account for the vast bulk of deployed CSP capacity, with PTC systems contributing currently for 64% of total projects. Most second generation CSP plants are made up of PTC, SPT, and LFR, with Rankine cycle efficiencies ranging from 38 to 45% and maximal cycle temperatures reaching 565 °C. Almost all new second generation CSP plants are outfitted with thermal energy storage systems. These second generation CSP facilities may attain an annual solar-electric efficiency of roughly 10–20% because of their high cycle efficiency, compared to 9–16% for first-generation CSP systems [123]. The third generation of CSP plants focuses on increasing the maximum cycle temperature using more modern materials for heat transmission, thermal storage, and working fluid in the thermal cycle. All third-generation CSP technologies, however, are still in the demonstration stage, with no commercial applications available [124]. The primary goal of third-generation CSP is to minimize the LCOE by increasing solar electric efficiency when operational temperatures rise over 600 °C [124].

Fig 24

  1. Download : Download high-res image (878KB)
  2. Download : Download full-size image

Fig. 24. Different CSP generation comparison [123]. (With permission, License Number: 5442921467985).

According to the European Solar Thermal Energy Association, the International Energy Agency, and Greenpeace, CSP might provide 3–3.6% of the global energy supply in 2030 and 8–11.8% by 2050. This suggests a necessity for a two-digit capacity increase in the next years, which has not yet been shown [125]. Other projections indicate that the cost of CSP might fall to $0.05/kWh by 2025 [126].

Developers of CSP plants using molten-salt TES systems are facing several challenges including the reduction of molten salt cost and reducing the risk of molten salt freezing. Parasitic use, antifreeze costs, and circulation pumping costs are all issues. Reducing the cost of the thermal storage asset used by the plant is one of the primary objectives of decreasing the LCOE of CSP. According to IRENA [127], CSP systems with four to eight hours of thermal storage capacity have total installed costs ranging from 3183 $/kW to 8645 $/kW. Projects with eight hours or more of thermal storage capacity have a narrower range, ranging from $4077 to $5874 per kW. According to a recent IRENA assessment [128], significant progress in lowering the prices of both sensible and latent heat thermal storage is projected over the next two decades, with costs as low as 12 $/kWh when incorporated into CSP, PV, or Wind projects. Table 6 lists some of the TES-related objectives for the coming years. The examination of common material qualities and main physical attributes will be used to develop new HTFs in the future. Corrosion, flammability, toxicity, thermal stability, cost, and availability are all common material properties [129].

Table 6. Primary TES with CSP technical innovation objectives [128].

Parameter Latent Sensible Thermochemical
2018 2030 2050 2018 2030 2050 2018 2030 2050
LCOE ($/kWh) 25–90 25–35 < 12 25–30 < 15 < 12 Under Research Pilot Scale (80 to 160) Demonstration < 80
Efficiency (%) > 90 > 92 > 95 > 90 > 92 > 95 40–50
Lifetime (Cycles) 3000 – 5000 4000 – 5000 5000 – 10,000 < 10,000 > 10,000 < 100 500 – 1000 > 1000 – 3000
Energy Density (kWh/m3) 30–85 70–200 800 – 1200
Working Temperature ( °C) < 600 600 – 750 700 – 850 < 565 600 – 700 > 700
  • 700

    – 850

  • 500 – 900

500 – 1000

5. Technical and economic challenges

Several technological and economic problems must be overcome by concentrated solar power plants, thermofluids and heat transfer fluids, and thermal energy storage systems. Economic problems include high capital costs, pricing unpredictability, finance, lack of scale, material prices, availability, and operational expenses. Technological obstacles include the variability of solar resources, integration with the grid, corrosion, thermal stability, and system complexity. These problems underline the need for ongoing innovation and investment in CSP technology to make it more cost-effective and efficient, as well as to overcome hurdles to large-scale deployment that are both technological and economic. In addition, there is a need for governmental support and regulatory frameworks that encourage the development of CSP technology, which may assist in accelerating the transition to a future that is powered by clean energy.

The fluctuation of solar resources brought on by meteorological circumstances such as clouds and dust may have a negative impact on the effectiveness of CSP facilities. Thermal energy storage technologies that are utilized in CSP plants have the potential to be negatively impacted by thermal losses as well as the complexity of the system. Because of their inherent unpredictability, integrating them into the grid may be a difficult task, and regular maintenance is necessary to ensure that their effectiveness is maintained. CSP plants are expensive to build, they face uncertain electricity prices and financing challenges, and they lack economies of scale due to the early stages of the industry. All these factors contribute to the relatively high cost of CSP power in comparison to the cost of power generated by other renewable energy sources [125,[130], [131], [132], [133], [134]].

Thermofluids and heat transfer fluids used in Concentrated Solar Power (CSP) plants present several obstacles, both technically and economically. Damage may be caused by these fluids due to their corrosive nature and high temperatures, which can also shorten their lifetime and weaken their thermal stability over time. The management of material compatibility may be difficult at times, and fluid deterioration can result in decreased productivity. The price of fluids that have been specifically created for an application may be rather high, and certain fluids are not easily accessible, necessitating unique handling and shipping procedures. Recycling and disposing of these fluids may also be a costly and difficult task for the environment to do [[135], [136], [137]].

The efficiency of systems that store thermal energy may fluctuate, and thermal losses can cause a reduction in that efficiency, which can result in greater expenses to operate the system. Material compatibility is essential in the struggle against corrosion and other problems. Moreover, larger systems might be more complicated, which can result in increased expenses for both construction and maintenance. It may be tough and costly to scale up thermal energy storage systems because of the demand for specialized equipment and materials. The materials that are utilized in these systems can be rather costly. The need for heat tracing and insulation may lead to relatively high operational expenses, which is especially true for molten salt systems [138,132,139,140].

For the CSP industry to successfully overcome these technological and economic hurdles, there must be ongoing innovation and success in overcoming these technological and economic hurdles, there must be ongoing innovation as well as investment in the research and development of new technologies. Efficiency gains and cost savings may be achieved via the use of various operational, material, and design enhancements. Accelerating the deployment of CSP technology and overcoming hurdles to the market entrance may be made possible with the aid of policy support and regulatory frameworks that favor the development of CSP technology. In the end, the capacity of the CSP sector to become more cost-effective and competitive with other sources of renewable energy will determine how successful the industry will be.

6. Conclusions

The CSP technology is an efficient renewable energy technology for power generation which attracted the attention of researchers. CSP technology can generate electricity with high capacities in wide areas worldwide with total solar to electricity efficiency reached more than 16%. By comparing around 143 CSP projects worldwide with 114 in operation, 20 now non-operational or decommissioned, and 9 under construction to begin operations in 2022 and 2023. The comparison showed that the Spain, the United States, and China are the leading countries in the use of CSP plants. Spain has the most installed capacity with a total of 2.3 GW and 51 projects built around the country, all of which are operational. Among the four common CSP technologies, the most utilized technology is parabolic trough collectors (PTC), with 91 projects, followed by solar thermal towers with 34 projects, linear Fresnel reflectors with 16 projects, and just two dish projects, both of which are decommissioned. Around 75% of installed capacity utilized the PTC technology. Furthermore, the linear Fresnel reflectors technology was found to have the largest land usage factor among the other technologies. However, the needed solar field area per 1 MW of capacity was found to be roughly 11,000 m2 for both linear Fresnel and Power Tower. Further, Covid-19 Pandemic had a detrimental impact on the deployment of CSP plants, with just 9 projects completed during that period (2020 – 2022). The LCOE reached a minimum value of 0.049 – 0.22 $/kWh for the hybrid integration method of PV and wind with the CSP.

Based on the current analysis, the following recommendations are essential for the next study in the area of hybrid renewable energy systems and TES, according to the findings of this study.

  • 1

    The design of the TES system is dependent on a variety of elements like the solar multiple of the CSP plant and the capacity of the power block. Thus, an optimization study is required to establish the optimal size of TES systems so that the LCOE may be as low as feasible.

  • 2

    A water footprint analysis and the development of water-saving technologies are essential for optimizing the use of water resources in CSP plants. This is because water is essential for the local communities where CSP projects are being built, as well as for the construction of CSP projects in arid areas.

  • 3

    It seems that hybrid PV/Wind/CSP using TES is a practical alternative with a high capacity factor and a low LCOE, which makes it a competitive choice for nations like Jordan that have higher DNI and GHI values.

  • 4

    A high-capacity factor is also present in hybrid CSP/PV/Wind systems with BESS, but the high LCOE indicates it may not be practical at present. Despite this, it is possible that in the next years, BESS may emerge as a viable choice because of further research and falling prices. PHS and CAES are both costly and contribute to an increased LCOE.

  • 5

    More research needs to be done on energy storage systems and heat transfer fluids to bring down the costs of renewable energy systems and improve their performance.

  • 6

    It is necessary to do further research can be directed toward the implementation of the Direct steam generation (DSG) technology in CSP.

Declaration of Competing Interest

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Data availability

  • No data was used for the research described in the article.

References